TEY Series Intelligent Temperature Controller


Quantity
Product description
  • Multi input signal, multi models for option. 
  • With measurement display, control output, alarm output, analog output, RS485 communication function. 
  • Multi PID control algorithms for option, with self-tuning function
  • Suitable for industrial machinery, machine tools, general measuring instruments and equipment.
  • Short shell, integrated digital tube.

Ordering information

Models

Specifications

Electrical parameters

Sample rate2 times per second
Relay capacityAC 250V /3A Life of rated load>100,000 times
Power supplyAC/DC 100 ~ 240V (85-265V),DC 24V
Power consumption< 10VA
EnvironmentIndoor use only, temperature: 0~50 no condensation,
humidity<85%RH, altitude<2000m
Storage
enenvironment
-10 ~ 60, no condensation
SSR outputDC 24V pulse voltage, load<30mA
Current outputDC 4 ~ 20mA load<500Ω, temperature drift 250PPM
Communication portRS485 port Modbus-RTU protocol, max input 30 units
Insulation impedanceInput, output, power VS meter cover >20MΩ
ESDIEC/EN61000-4-2 Contact ±4KV /Air ±8KV perf.Criteria B
Pulse traip
anti-interference
IEC/EN61000-4-4 ±2KV perf.Criteria B
Surge immunityIEC/EN61000-4-5 ±2KV perf.Criteria B
Voltage drop & short
interruption immunity
IEC/EN61000-4-29 0% ~ 70% perf.Criteria B
Isolation voltageSignal input, output, power: 1500VAC 1min,
<60V low voltage circuit: DC500V,1min
Total weightAbout 400g
Cover materialThe shell and panel frame PC/ABS (Flame Class UL94V-0)
Panel materialPC
Power failure memory10 years, times of writing: 1 million times
Safety StandardIEC61010-1 Overvoltage category ,pollution level 2,
level(Enhanced insulation)

 

Measured signal specifications:

Input typeMeasure rangeResolutionAccuracyInput impedance
/auxiliary current
Comm.
parm. code
K1-50 ~ 120010.5%F.S±3digits>500KΩ0
K2-50.0 ~ 999.90.20.5%F.S±1>500KΩ16
J10 ~ 120010.5%F.S±1>500KΩ1
J20.0 ~ 999.90.20.5%F.S±1>500KΩ17
E10 ~ 85010.5%F.S±3digits>500KΩ2
E20.0 ~ 850.00.30.5%F.S±1>500KΩ18
T1-50 ~ 40010.8%F.S±3>500KΩ3
T2-50.0 ~ 400.00.40.8%F.S±3>500KΩ19
B250 ~ 180011%F.S±2>500KΩ4
R-10 ~ 170011%F.S±2>500KΩ5
S-10 ~ 160011%F.S±2>500KΩ6
N1-50 ~ 120010.8%F.S±1>500KΩ7
N2-50.0 ~ 999.90.20.8%F.S±1>500KΩ20
PT100-1-200.0 ~ 600.00.20.5%F.S±0.30.2mA8
PT100-2-200 ~ 60010.5%F.S±3digits0.2mA21
JPT100-1-200.0 ~ 500.00.20.5%F.S±0.30.2mA9
JPT100-2-200 ~ 50010.5%F.S±3digits0.2mA22
CU50-1-50.0 ~ 150.00.20.5%F.S±30.2mA10
CU50-2-50 ~ 15010.5%F.S±30.2mA23
CU100-1-50.0 ~ 150.00.20.5%F.S±10.2mA11
CU100-2-50 ~ 15012bit0.5%F.S±10.2mA24
0 ~ 50mV-1999 ~ 999912bit0.5%F.S±1>500kΩ12
0 ~ 400Ω-1999 ~ 999912bit0.5%F.S±10.2mA13
*4 ~ 20mA-1999 ~ 999912bit0.5%F.S±1<50Ω14
*0 ~ 10V-1999 ~ 999912bit0.5%F.S±1>1MΩ15

 

 

 

 

 

 

  • Multi input signal, multi models for option. 
  • With measurement display, control output, alarm output, analog output, RS485 communication function. 
  • Multi PID control algorithms for option, with self-tuning function
  • Suitable for industrial machinery, machine tools, general measuring instruments and equipment.
  • Short shell, integrated digital tube.

Ordering information

Models

Specifications

Electrical parameters

Sample rate2 times per second
Relay capacityAC 250V /3A Life of rated load>100,000 times
Power supplyAC/DC 100 ~ 240V (85-265V),DC 24V
Power consumption< 10VA
EnvironmentIndoor use only, temperature: 0~50 no condensation,
humidity<85%RH, altitude<2000m
Storage
enenvironment
-10 ~ 60, no condensation
SSR outputDC 24V pulse voltage, load<30mA
Current outputDC 4 ~ 20mA load<500Ω, temperature drift 250PPM
Communication portRS485 port Modbus-RTU protocol, max input 30 units
Insulation impedanceInput, output, power VS meter cover >20MΩ
ESDIEC/EN61000-4-2 Contact ±4KV /Air ±8KV perf.Criteria B
Pulse traip
anti-interference
IEC/EN61000-4-4 ±2KV perf.Criteria B
Surge immunityIEC/EN61000-4-5 ±2KV perf.Criteria B
Voltage drop & short
interruption immunity
IEC/EN61000-4-29 0% ~ 70% perf.Criteria B
Isolation voltageSignal input, output, power: 1500VAC 1min,
<60V low voltage circuit: DC500V,1min
Total weightAbout 400g
Cover materialThe shell and panel frame PC/ABS (Flame Class UL94V-0)
Panel materialPC
Power failure memory10 years, times of writing: 1 million times
Safety StandardIEC61010-1 Overvoltage category ,pollution level 2,
level(Enhanced insulation)

 

Measured signal specifications:

Input typeMeasure rangeResolutionAccuracyInput impedance
/auxiliary current
Comm.
parm. code
K1-50 ~ 120010.5%F.S±3digits>500KΩ0
K2-50.0 ~ 999.90.20.5%F.S±1>500KΩ16
J10 ~ 120010.5%F.S±1>500KΩ1
J20.0 ~ 999.90.20.5%F.S±1>500KΩ17
E10 ~ 85010.5%F.S±3digits>500KΩ2
E20.0 ~ 850.00.30.5%F.S±1>500KΩ18
T1-50 ~ 40010.8%F.S±3>500KΩ3
T2-50.0 ~ 400.00.40.8%F.S±3>500KΩ19
B250 ~ 180011%F.S±2>500KΩ4
R-10 ~ 170011%F.S±2>500KΩ5
S-10 ~ 160011%F.S±2>500KΩ6
N1-50 ~ 120010.8%F.S±1>500KΩ7
N2-50.0 ~ 999.90.20.8%F.S±1>500KΩ20
PT100-1-200.0 ~ 600.00.20.5%F.S±0.30.2mA8
PT100-2-200 ~ 60010.5%F.S±3digits0.2mA21
JPT100-1-200.0 ~ 500.00.20.5%F.S±0.30.2mA9
JPT100-2-200 ~ 50010.5%F.S±3digits0.2mA22
CU50-1-50.0 ~ 150.00.20.5%F.S±30.2mA10
CU50-2-50 ~ 15010.5%F.S±30.2mA23
CU100-1-50.0 ~ 150.00.20.5%F.S±10.2mA11
CU100-2-50 ~ 15012bit0.5%F.S±10.2mA24
0 ~ 50mV-1999 ~ 999912bit0.5%F.S±1>500kΩ12
0 ~ 400Ω-1999 ~ 999912bit0.5%F.S±10.2mA13
*4 ~ 20mA-1999 ~ 999912bit0.5%F.S±1<50Ω14
*0 ~ 10V-1999 ~ 999912bit0.5%F.S±1>1MΩ15

 

 

 

 

 

 



เว็บไซต์นี้มีการใช้งานคุกกี้ เพื่อเพิ่มประสิทธิภาพและประสบการณ์ที่ดีในการใช้งานเว็บไซต์ของท่าน ท่านสามารถอ่านรายละเอียดเพิ่มเติมได้ที่ นโยบายความเป็นส่วนตัว and นโยบายคุกกี้
Compare product
0/4
Remove all
Compare
Powered By MakeWebEasy Logo MakeWebEasy