SUP-LUGB Vortex flowmeter with temperature & pressure compensation

SUP-LUGB Vortex flowmeter work on the principle of generated vortex and relation between vortex and flow by theory of Karman and Strouhal, which specialize in measurement of steam, gas and liquid of lower viscosity.

จำนวน
Product description

Characteristics

  • Pipe diameter: DN10-DN500
  • Accuracy: 1.0%  1.5%
  • Range Ratio:  1:8
  • Ingress protection: IP65

Specification

 ProductVortex flowmeter with temperature & pressure compensation
ModelSUP-LUGB
Diameter nominalDN10~DN500
InstallationWafer connection: DN10-DN500(priority PN2.5MPa)  Flange connection: DN10-DN80(priority PN2.5MPa);DN100-DN200(priority PN1.6MPa);DN250-DN500(priority PN1.0MPa)
Accuracy1.5%, 1.0%
Range Ratio8:1
Medium Temperature-20°C ~ +150°C, -20°C ~ +260°C, -20°C ~ +320°C, -20°C ~ +420°C
Output signal4-20mA
FrequencyRS485 communication (Modbus RTU)
Power supply24VDC±5%  Li battery(3.6VDC)
Ingress protectionIP65
Body MaterialsStainless shell
Display128*64 dot matrix LCD