Specifications
Model | PDS51-2S2R2-E | PDS51-4T2R2-E | PDS51-4T004-E | PDS51-4T5R5-E | PDS51-4T7R5-E | PDS51-4T011-E |
DC Input | ||||||
Max. Input Voltage [V] | 450 | 900 | ||||
Start Voltage [V] | 100 | 220 | ||||
Min. Input Voltage [V] | 70 | 200 | ||||
MPPT Voltage Range [V] | 200-400 | 400-750 | ||||
Recommended Input Working Voltage [V] | 330 | 560 | ||||
Num. of DC Input [MC4 Connection] | 1 | 2 | ||||
Booster function | Standard | / | ||||
AC Input | ||||||
Input Voltage [V] | 1PH 150-230 | 3PH 280-480 | ||||
Input Frequency [Hz] | 50/60 | |||||
AC Output | ||||||
Output Power [kW] | 2.2 | 2.2 | 4 | 5.5 | 7.5 | 11 |
Rated Current [A] | 9.6 | 5.1 | 9 | 13 | 17 | 25 |
Output Voltage [V] | 3PH 0-220 | 3PH 0-380 | ||||
Output Voltage [Hz] | 0-50/60 | |||||
Control Performance | ||||||
Control Mode | V/F, SVC | |||||
Supported Motor Type | Asynchronous and Synchronous | |||||
Overload Capability | 150% of rated current: 60 seconds; 180% of rated curent: 1 second | |||||
Protection | ||||||
Undervoltage Protection | Integrated | |||||
Overvoltage Protection | Integrated | |||||
Overload Protection | Integrated | |||||
Short-Circuit Protection | Integrated | |||||
Overhead Protection | Integrated | |||||
Lack of Water Protection | Integrated | |||||
Surge Protection | Integrated | |||||
General Data | ||||||
Ingress Protection Degree | IP65 | |||||
Cooling Mode | Natural Convection | |||||
External Interface | External LED Keypad | |||||
Communication Interface | 4G/2G GPRS DTU | |||||
Ambient Operation Temperature | -20°C ~ 60°C (>45°C, rated power will be derated for 1% by every additional 1°C) | |||||
Operation Altitude | recommend <3000m (the rated power will be decreased for 1% by every additional 100m when the altitude is >2000m) | |||||
Dimension [H*W*D] [mm] | 295*396*180.5 | 315*430*186 | ||||
Weight [kg] | 9.1 | 12 | ||||
Standard Warranty [Month] | 36 | |||||
Certification Standards | CE |