Product Description
The chlorine gas sensor developed by our company adopts electrochemical sensor. The measurement process is sensitive and anti-interference ability is strong. With our unique compensation algorithm and multi-segment standard gas calibration, the chlorine sensor is highly accurate and stable. The sturdy waterproof housing can effectively protect the sensor module, preventing the erosion of the sensor by soot and water vapor, and prolonging the service life. Suitable for workshops, chemical plants, electronic industry, closed living places and other occasions where real-time monitoring of chlorine concentration is required.
Parametes
Power Supply | 10~30V DC |
Output Signal | 4-20mA/0-5V/0-10V/RS485 |
Power Consumption | 0.25W |
Working Temperature | -20~50°C |
Working Humidity | 15~90%RH No Condensation |
Pressure Range | 90~110kPa |
Stability | 2% signal value/month |
Chlorine Zero Drift | ±3%FS |
Repeatability | 3% |
Service Life | 24Months |
Measurement Range | 0~20ppm/0~50ppm/0~100ppm |
Accuracy | ±10% |
Resolution | 0~100ppm:1ppm 0~20ppm/0~50ppm:0.1ppm |
Response Time | 60s |
Preheating Time | 5mins |
Three Types of Chlorine Gas Sensor
Wall mounted chlorine gas sensor
The Wall mounted chlorine gas sensor is mainly used to measure chlorine gas in the atmosphere, which diffuses through a waterproof breathable membrane into the interior of the device and is measured by the sensor. This chlorine gas sensor supports a wide range of customizations and can be added with an OLED screen to view data in real time. It is also possible to add specific epitaxial probes to measure the chlorine concentration in certain pipes. The default wire length of the extension probe is 80cm, and the maximum length can be 15m. In addition, it can be integrated with a temperature and humidity sensor to realize the three-in-one measurement of temperature, humidity and chlorine gas. This chlorine sensor is mainly used for real-time detection of chlorine concentration in factories, mines, chemicals, pharmaceuticals, material synthesis and environmental protection.
Measure range: 0~20ppm, 0~50ppm or 0~100ppm
Output signal: RS485/4-20MA/0-5V/0-10V/WIFI/LORA
Duct type chlorine gas sensor
Duct type chlorine gas sensor is a specialized device for detecting the concentration of chlorine gas in closed pipelines. During installation, a hole is punched in the pipe and the stainless steel end is inserted into the pipe and secured. Stainless steel pipes have good corrosion resistance and can work in pipelines for a long time. Built-in waterproof rubber strip protects the sensor and increases its service life. The gas entering the stainless steel pipe diffuses through the waterproof breathable membrane and comes into contact with the sensor thus measuring the value. An OLED screen can be added to this device to view the data in real time on site. Other ranges can also be customized.
Measure range: 0~20ppm, 0~50ppm or 0~100ppm
Output signal: RS485/4-20MA/0-5V/0-10V/WIFI/LORA
Explosion-proof chlorine gas sensor
Explosion-proof chlorine gas sensor overall shell made of stainless steel, high-quality explosion-proof shell, waterproof and dustproof effect. Built-in industrial-grade electrochemical sensors, strong anti-interference ability, even in the flammable and explosive harsh environment can work. Equipment with liquid crystal display and sound and light alarm function. When the management personnel can not close contact with the equipment, they can configure the parameters through the infrared remote control function. This chlorine sensor supports customized range to meet the different needs of customers. Commonly used in gas stations, chemical plants, gas stations and other dangerous places.
Measure range: 0~20ppm, 0~50ppm or 0~100ppm
Output signal: RS485/4-20MA/0-5V/0-10V