Product Description of PIR Motion Sensor
RS-HW-N01-3-EX is a high-stability PIR motion sensor. It adopts advanced signal analysis and processing technology and has super high detection and anti-false alarm performance. When an intruder passes through the detection area, the detector will automatically detect the human activity in the area. If there is dynamic movement, an alarm will be generated. The device has 485 output and standard ModBus-RTU protocol, which can be developed again. The product is suitable for security prevention in family residential areas, real estate villas, factories, warehouses, shopping malls, office buildings and other places.
Renke PIR Motion Sensor Parameters
RS-HW-N01 PIR motion sensor | |
Power supply | 10~30V DC |
Power consumption | 0.4W |
Sensor type | dual-element pyro-infrared sensor |
Alarm duration | 30s, 10s, 5s output optional (default 5s) |
Delayed alarm | software setting (delay for alarm occurrence) |
Installation method | ceiling |
Installation height | 2.5~6m |
Detection range | diameter 6m (when the installation height is 3.6m) |
Detection angle | 360° in all directions |
Signal output | RS485 |
Working environment | -20~+50, 0%RH~95%RH (non-condensing) |
Product Description of Microwave Motion Sensor
RS-WB-N01-3-EX is a high stability radar microwave detector. It detects moving targets by compression and stretching of microwaves. The infrared + microwave dual-detection sensor can measure not only the distance of moving objects, but also the speed of movement. Compared with infrared light, microwaves have a longer sensing distance and a wider angle, and can penetrate glass and thin wood. Depending on the power, it can penetrate walls of different thicknesses, and the sensing distance does not decrease with changes in temperature.
Renke Microwave Motion Sensor Parameters
Renke microwave motion sensor | |
Power supply | 10~30V DC |
Power consumption | 0.4W |
Sensor type | microwave sensor |
Alarm duration | adjustable register 0-65535s (fast dialing can only adjust fixed time) |
Delayed alarm | software setting (triggered during this time, the device alarms after the delay ends. Intermittent triggering, the device does not alarm after the delay ends) |
Working frequency | 24.00~24.25GHz |
Installation method | ceiling |
Installation height | 2.5~6m |
Detection range | diameter 6m (when the installation height is 3.6m) |
Detection angle | 360° in all directions |
Signal output | RS485 |